Showing posts with label anemometer. Show all posts
Showing posts with label anemometer. Show all posts

Thursday, November 15, 2012

Laser Doppler anemometer

Doppler Effect is a method for measuring linear velocity. When a narrow laser beam ( or radio beam or ultrasonic beam) is focused on an abject, the beam will be reflected back to the source. But if the object is moving, the frequency of the signal received back will differ from that of the transmitted signal. This difference in frequency (Doppler shift) becomes a measure of the velocity of the object .

LDA is used to measure flow (especially, high frequency turbulence fluctuations). This device can measure velocity of flow precisely and they don’t disturb the flow during the measurement process.

Description of Laser Doppler anemometer

The main parts of this device are as follows

  1. A laser source (an argon laser or He-Ne laser).
  2. A beam splitter that splits the laser beam into two equal intensity beams.
  3. Alens to focus the two split lazer beams at an intersection point.
  4. A photomultiplier tube (PMT)


For a flow whose velocity is to be determine, it is to be noyted that the flow should contain small particles to scatter the light. The particle concentration should be very small.

Operation of Laser Doppler anemometer


  1. The laser source sends a beam that is split by a beam splitter into two beams.
  2. The two parallel beams are focused by the lens L1 such that they intersect at a point in the test section were flow ( with particles ) exists. In the region of intersection, interference fringes are formed.
  3. The particles (carried along with the flow) that pass through the intersection of the beams scatter the light from both the beams.
  4. The scattered light experiences a Doppler shift in frequency that is directly proportional to the flow velocity.
  5. The light is collected by a photomultiplier tube (PMT). The device is constructed such that the direct and scattered beams travel in the same optical path so that an interference will be observed at the PMT that is proportional to frequency shift. This shift then gives an indication of flow velocity.
  6. A signal processor is used to retrieve velocity data from the PMT.


Advantages of Laser Doppler anemometer


  1. The device does not disturb the flow during measurement
  2. The device measure velocity directly
  3. Volume of sensing part can be very small
  4. Highly accurate
  5. Can be used to measure flow of both gases and liquids.


Disadvantages of Laser Doppler anemometer


  1. Requires transparent channels
  2. Cannot be-used on clean flows


Applications of Laser Doppler anemometer


  1. Wind tunnel studies
  2. Blood flow measurement
  3. Sensing of wind velocity
  4. Used in the field of combustion

Friday, February 18, 2011

Turbine Type Anemometer:

When a rotor attached to a permanent magnet polarized at 90’ to the axis of rotation, and if the rotor is made to rotate due to the fluid velocity V, the rotating magnetic fluid will be cut by the pickup coil generating voltage pulses. The frequency of voltage pulses is proportional to flow rate. Hence the measure of frequency of voltage pulses becomes a measure of flow rate.

Description of Turbine Meter:


The main parts of the turbine meter are as follows:

A turbine wheel (rotor)
A permanent magnet polarized at 90’ to the axis of rotation which is attached to one of the blades of the rotor.
A pickup coil placed external to the meter housing.
A frequency meter or counter attached to the pickup coil.

Operation of Turbine Meter:


turbine type anemometer
The turbine meter is fixed to the pipe carrying the fluid whose volume flow rate is to be measured.
The fluid strikes the blades of the rotor and makes it to rotate. When the rotor rotates, the permanent magnet attached to the rotor blade also rotates, which in turn produces a rotating magnetic field.
Each time the magnet passes the pickup coil, the magnetic flied is being cut generating a voltage pulse. The frequency of voltage pulses is indicated by a frequency meter.
This frequency of voltages pulses becomes a measure of flow rate when calibrated.
The volume flow rate “Q” is given by Q = F/C

Where F = total number of pulses
C = flow Coefficient

Applications:


They are extensively used in weather stations to measure wind velocity.
They are used to measure water flow in rivers and streams.
Compact models are used to measure flow in tubes and pipes.

Advantages of turbine Meter:


Recording and controlling can be done from a distance (telemetry).
High accuracy (error is -/+ 0.5%).
Has good dynamic response.
The pressure drop in the fluid is low.
It is easy to install and maintain.

Limitations of turbine meter:


Error increases if the flow rate is low.
Bearing friction and wear may alter the linear output of this instrument.
For a distance, a straight run of pipe ahead of instrument is required.