Moving coil Type Velocity Transducer

Basic Principle of Moving coil Type Velocity Transducer


  1. A coil moves in a magnetic field according to the velocity applied.
  2. The voltage in the coil becomes a measure of the velocity when calibrated.

Description of Moving coil Type Velocity Transducer


  1. The instrument has permanent pole pieces which generate the magnetic field.
  2. There is a pivoted arm on which a coil is mounted.
  3. There is a mass attached to the end of the coil.
  4. The whole device is contained in an antimagnetic case.

Operation of Moving coil Type Velocity Transducer


  1. The velocity to be measured is applied to the arm.
  2. Due to this coil moves in the magnetic field.
  3. A voltage is generated on account of motion of the coil in the magnetic field.
  4. The output voltage is proportional to the velocity.

Advantages of Moving coil Type Velocity Transducer


  1. The antimagnetic case reduces the effects of stray magnetic field.
  2. Damping is obtained electrically.
  3. There is high stability under varying temperature conditions.

Applications of Moving coil Type Velocity Transducer

These transducers are used for measuring velocities in linear, sinusoidal or random manner.

Sunday, April 15, 2012

Moving magnet type velocity Transducer

Basic principle of Moving magnet type velocity Transducer
When a permanent magnet moves inside a coil, the change in the length of the air gap varies the reluctance. Hence the output voltage is directly proportional to the rate of change of the length of the air gap (change in length produced by velocity). Thus the output voltage becomes a measure of the velocity when calibrated.

Description of Moving magnet type velocity Transducer

    Moving magnet type velocity Transducer
  1. The sensing element which is a rod is a permanent magnet.
  2. The rod is rigidly coupled to the device whose velocity is being measured.
  3. There is a coil surrounding the permanent magnet.
  4. The permanent magnet is movable, that is, it can move in and out of the coil.

Operation of Moving magnet type velocity Transducer

  1. The instrument is fixed to the device whose velocity is to measured.
  2. Due to the application of the velocity, the permanent magnet moves in or out of the coil. Due to its motion, the length of the air gap varies.
  3. The output voltage also varies due to the motion of the magnet and the amplitude of the voltage is directly proportional to velocity.
  4. The polarity of the output voltages determines the direction of the velocity.

Advantages of Moving magnet type velocity Transducer

  1. Its maintenance is negligible.
  2. The output voltage is linearly proportional to velocity.
  3. Cost of manufacture is less.

Disadvantages of Moving magnet type velocity Transducer

  1. Performance is affected by stray magnetic fields and hence noise is caused.
  2. Frequency response is poor.
Application
Used as a velocity transducer to convert velocity to measureable voltage.

Tuesday, March 27, 2012

Pirani gauge – A Thermal conductivity Gauge

The Pirani Gauge is a type of Thermal Conductivity Gauges.

Basic principle of Pirani gauge

A conducting wire gets heated when electric current flows through it. The rate at which heat is dissipated from this wire depends on the conductivity of the surrounding media. The conductivity of the surrounding media inturn depends on the densisty of the surrounding media (that is, lower pressure of the surrounding media, lower will be its density). If the density of the surrounding media is low, its conductivity also will be low causing the wire to become hotter for a given current flow, and vice versa.

Description of Pirani gauge

Pirani gaugeThe main parts of the arrangement are:
  1. A pirani gauge chamber which encloses a platinum filament.
  2. A compensating cell to minimize variation caused due to ambient temperature changes.
  3. The pirani gauge chamber and the compensating cell is housed on a wheat stone bridge circuit as shown in diagram.

Operation of Pirani gauge

  1. A constant current is passed through the filament in the pirani gauge chamber. Due to this current, the filament gets heated and assumes a resistance which is measured using the bridge.
  2. Now the pressure to be measured (applied pressure) is connected to the pirani gauge chamber. Due to the applied pressure the density of the surrounding of the pirani gauge filament changes. Due to this change in density of the surrounding of the filament its conductivity changes causing the temperature of the filament to change.
  3. When the temperature of the filament changes, the resistance of the filament also changes.
  4. Now the change in resistance of the filament is determined using the bridge.
  5. This change in resistance of the pirani gauge filament becomes a measure of the applied pressure when calibrated.

Note: [higher pressure – higher density – higher conductivity – reduced filament temperature – less resistance of filament] and vice versa.

Applications of Pirani gauge

Used to measure low vacuum and ultra high vacuum pressures.

Advantages of Pirani gauge

  1. They are rugged and inexpensive
  2. Give accurate results
  3. Good response to pressure changes.
  4. Relation between pressure and resistance is linear for the range of use.
  5. Readings can be taken from a distance.

Limitations of Pirani gauge

  1. Pirani gauge must be checked frequently.
  2. Pirani gauge must be calibrated from different gases.
  3. Electric power is a must for its operation.

Wednesday, November 2, 2011

A Complete Note on Difference between Lab View, PLC and DCS

Yesterday, i receive a question from one of my facebook fan asking " sir could u please say the difference between labview and plc and dcs "

As far as i know Lab View is completely different from DCS and PLC, Labview is a software.

LabVIEW is a graphical programming environment used by millions of engineers and scientists to develop sophisticated measurement, test, and control systems using intuitive graphical icons and wires that resemble a flowchart. It offers unrivaled integration with thousands of hardware devices and provides hundreds of built-in libraries for advanced analysis and data visualization – all for creating virtual instrumentation. The LabVIEW platform is scalable across multiple targets and OSs, and, since its introduction in 1986, it has become an industry leader.

A distributed control system (DCS) refers to a control system usually of a manufacturing system, process or any kind of dynamic system, in which the controller elements are not central in location (like the brain) but are distributed throughout the system with each component sub-system controlled by one or more controllers. The entire system of controllers is connected by networks for communication and monitoring.

A programmable logic controller (PLC) or Programmable controller is a digital computer used for automation of electromechanical processes, such as control of machinery on factory assembly lines, amusement rides, or light fixtures. PLCs are used in many industries and machines. Unlike general-purpose computers, the PLC is designed for multiple inputs and output arrangements, extended temperature ranges, immunity to electrical noise, and resistance to vibration and impact. Programs to control machine operation are typically stored in battery-backed-up or non-volatile memory. A PLC is an example of a hard real time system since output results must be produced in response to input conditions within a bounded time, otherwise unintended operation will result.

The differences between DCS and PLC are: DCS (Distributed Control System) is a CONTROL SYSTEM that works using several controllers and coordinates the work of all these controllers. Each controller is handling a separate plant. This controller is referred to the PLC.

The PLC (Programmable Logic Controller) is a CONTROLLER which can be re-program back. If the PLC is only a stand-alone and not combined with other PLCs, it is called as DDC. It means PLC is a sub system of a large system called DCS.

What’s difference between PLC and DCS by its definition:
PLC is a controller or processor that can be programmed (programmable) whose function is to run (execute) logic functions. Logic means the discrete / sequence function is usually handled by the relay. From the beginning of the vendors who carry the name of the PLC is engaged in the business discrete / sequence control.

Regardless of the distributed control system (as opposed to the DDC = Direct Digital Control) is categorized as a DCS. In DDC all system controls are done in the central processor so that if it failed, the entire control plant will also failed. DDC is mostly used as a Regulatory Control. And from the beginning vendors that carry the name of DCS is to use the product as a regulatory control.

Different in functionality means that the DCS and PLC can not be implemented on the same application.
1. DCS is not a large PLC. Because system architecture of DCS and PLC are different.
2. DCS is not PLCs that integrated into one large system. "Controller" in the PLC is more intended as a "Logic Controller", while “Controller” in the DCS is more intended as a "Process Controller".
3. Both DCS and PLC is a configurable and reconfigurable.

Saturday, October 15, 2011

Instrumentation and Control Interview Questions and Answers

I hope it is time for the final year students to prepare for placement and this post is to share Mr.Patel's Interview experience.

If you are looking for the Instrumentation interview question and answers, you can navigate to the bottom section of the post.

ESSAR instrumentation paper on 18th may, Gandhi nagar.

Hello friend, my name chandresh patel from government engineering college gandhinagar, sec-28 & want to share my experience about selection procedure of ESSAR.


Eligibility:-
60% aggregate marks.

Selection process:-

Online written test:-

4 sections:- Quantitative aptitude, Reasoning, English, Technical.

It is the most important round of the selection process. The first three sections are easy & if you prepare well for aptitude from R S Agrwal. Then it won’t be a problem. But the time is very less so u must be fast.

For the technical section, they asked basic question from the whole instrumentation. for this Section u must prepare well. They asked from all the subject of previous semester. So the basic fundamental must be clear.

Some of questions like....
  1. Range of any specific type thermocouple.
  2. About plc & dcs.
  3. Digital technology.(flip-flop etc...)
  4. Transducers & their principles.
  5. op-amp based question.
  6. 4-20ma related questions.
After this written section the result was declared & fortunately i was selected for group discussion.

Group discussion:
This part is put just for formality. No one was eliminated from this round.

Personal interview:-
There were two sections in personal interview.
  1. Technical.
  2. HR.

In technical, they asked me about myself, and then start some technical question related to plc & dcs. Control valves, three element boiler control, and cascade, discuss my 8th semester project. The sir was very friendly & asks me about my interest & it was great experience. The main thing is your confidence & must be confident.

In HR, they asked me very simple question like why do u want to join essar? , family background, why don’t u want to study further. just answer honestly. Don’t be over smart. After 15 days they send result to out college TPO. & i was selected.

Best of luck............

Download the eBook to know about the instrumentation  interview question and answers asked in the placement time click here

You can contact me through the below comments box, if you want any help in interview questions and answers.

Tuesday, August 23, 2011

Programmable Logic Controller - PLC


Hello friends, in this post I am going to start sharing a information related to a new topic Programmable Logic Controller which plays a very important role in automation of every industry.

Evolution of PLC ?


Manufacturing process require a sequence of operations in order to make a product.
And in this case sequencing can be done by manually or some type of controller.
In late 1960’s sequencing operations are performed by using a bank of relays wired to perform a particular job.
But there were drawbacks, logic systems where difficult to reprogram for production changes and also troubleshooting is very difficult.

To avoid the above drawbacks PLC’s are used.

PLC’s use the sum relay logic function and sequence is not hard wired but can be programmed and stored in a memory.
The contents of the memory are easily changed.
PLC’s are used first by automobile industries.

Sunday, June 5, 2011

Colleges Offering B.E Instrumentation and Control Engineering in India

Hello friends, This post is for students searching for colleges offering instrumentation and control engineering B.E course in India. I have list the college names and the university to which the college is affiliated to and location of the college.

Colleges in Delhi


College Name : Amity School of Engineering & Technology
University: Guru Gobind Singh Indraprastha University
State : Delhi
City : Nazafgarh
Contact Number: 011-28062106,28061487


College Name : Netaji Subhas Institute of Technology
University : University of Delhi
State : Delhi
City : New Delhi
Contact number: 011-25099050

Colleges in Assam


College Name : Assam Engineering College
University : Gauhati University
State : Assam
City : Guwahati
Contact number: +91-361-2570550

College Name : Jorhat Engineering College
University : Dibrugarh University
State : Assam
City : Jorhat
Contact number:913762330134

Colleges in Haryana


College Name : B.M. Institute of Engineering & Technology
University : Guru Jambeshwar University
State :Haryana
City : Sonepat
Contact number:01302230563, 2233662

Colleges offering Instrumentation and control engineering in Punjab

College Name : Sant Longowal Institute of Engineering and Technology
University : Punjab Technical University
State : Punjab
City : Sangrur
Contact number: 01672-280072, 284782

Colleges in Gujarat


College Name : Atmiya Group of Institutions
University : Gujarat State Technical Examinations Board
State : Gujarat
City : Rajkot
Contact number: 080-4169 7855

College Name : Government Engineering College
University : Gujarat Technological University
State : Gujarat
City : Gandhinagar
Contact number: 079-23253546, +91-79-23215167

College Name : Government Engineering College
University : Saurashtra University
State : Gujarat
City : Rajkot
Contact number: 0281-2924062

College Name : L.D. College Of Engineering
University : Gujarat Technological University
State :Gujarat
City : Ahmedabad
Contact number:91(79) 26302887, +91-79-26306752

College Name : Sarvajanik College of Engineering & Technology
University : Veer Narmad South Gujarat University.
State : Gujarat
City : Surat
Contact number: 91-0261-2240146, 91-0261-2240147

College Name : Shantilal Shah Engineering College
University : Bhavnagar University
State :Gujarat
City : Bhavnagar
Contact number: 91-0261-2445767, 2445509

College Name : Vishwakarma Government Engineering College
University : Gujarat University
State :Gujarat
City : Gandhinagar
Contact number: (079) 23293866, 23293006

Colleges in Madhya Pradesh


College Name : Medicaps Institute of Technology & Management
University : Rajiv Gandhi Proudyogiki Vishwavidyalaya(Technical University)
State : Madhya Pradesh
City : Indore
Contact number: 0731-4020492, 07312856294

College Name : Shri Vaishnav Institute of Technology & Science
University : Rajiv Gandhi Proudyogiki Vishwavidyalaya(Technical University)
State :Madhya Pradesh
City : Indore
Contact number:07321 - 224374, 0731-2349112, 0731-2349113

Colleges offering B.E Instrumentation and control engineering Course in Maharastra


College Name : DY Patil College Of Engineering
University : University of Pune
State :Maharashtra
City : Pune
Contact number: 020- 7653054, 020-7653058

College Name : Gangamai College of Engineering
University : North Maharashtra University
State :Maharashtra
City : Dhule
Contact number:+912562288170

College Name : N.D.M.V.P. Samaj's College of Engineering (NDMVPCOE)
University : University of Pune
State :Maharashtra
City : Nashik
Contact number:0253 - 2571439, 2582891, (0253)(O)2582823

College Name : Padmabhooshan Vasantraodada Patil Institute of Technology Budhgaon
University : University of Pune
State :Maharashtra
City : Sangli
Contact number: +91-233- 364245, +91-0233: 2366345, 2366317

College Name : Padmashree Dr. D. Y. Patil Institute of Engineering & Technology
University : University of Pune
State :Maharashtra
City : Pune
Contact number: 020-27421095 / 96 / 97

Updated : 28/7/11
College Name : Pravara Rural College of Engineering Loni
University : University of Pune
State : Maharashtra
City : Loni, Ahmednagar
Contact number:+91- 2422-273700, +91- 2422-273527

College Name : Vidyavardhini's College of Engineering and Technology
University : University of Mumbai(Bombay)
State :Maharashtra
City : Thane
Contact number:+91- 251 - 2338234 Ext 115 , 2339486

College Name : Watumull Institute of Electronics Engineering & Computer Technology
University : University of Mumbai(Bombay)
State :Maharashtra
City : mumbai
Contact number:(022) 24971506

Colleges in Karnataka


College Name : B M Sreenivasaih College OF Engineering
University : Visvesvaraya Technological University
State : Karnataka
City : Bangalore
Contact number: 080-26622130, 26614357

College Name : Siddaganga Institute of Technology
University : Visvesvaraya Technological University
State :Karnataka
City : Tumkur
Contact number: 0816-2092000


Colleges offering B.E Instrumentation and control engineering Course in Andhra Pradesh


College Name : Muffakham Jah College of Engineering and Technology
University : Osmania University
State : Andhra Pradesh
City : Hyderabad
Contact number:+91-40-23357195, 040-23352084 , +91-40-23351986, 040-23350605

College Name : Viswanadha Institute of Technology and Management
University : Jawaharlal Nehru Technological University, Hyderabad
State : Andhra Pradesh
City : Visakhapatnam
Contact number:08933-220587, 91 0891 2539007

Colleges in Tamil nadu


College Name : Arulmigu Meenakshi Amman College of Engineering
University : Anna University Chennai
State :Tamil Nadu
City : Tiruvannamalai
Contact number:04182-247226, 247518

College Name : Dr. Mahalingam College of Engineering and Technology
University : Anna University Chennai
State :Tamil Nadu
City : Coimbatore
Contact number: +(91)-(4259)-236030, 236040, 236050 , +(91)-(4259)-236070

College Name : Indira Gandhi College Of Engineering & Technology For Women
University : Anna University Chennai
State :Tamil Nadu
City : Kancheepuram
Contact number: 044 – 26531612, 27493423

College Name : Jayamatha Engineering College
University : Anna University
State :Tamil Nadu
City : Kanyakumari
Contact number: 04652-363440

College Name : Kongu Engineering College
University : Anna University Coimbatore
State : Tamil Nadu
City : Erode
Contact number:04294 - 220583, 04294 - 220562, 220171,226515

College Name : Maharaja Prithvi Engineering College
University : Anna University Chennai
State : Tamil Nadu
City : Coimbatore
Contact number:2272626 , 2270006

College Name : R.V.S. College of Engineering and Technology
University : Anna University Chennai
State :Tamil Nadu
City : Dindigul
Contact number:04551-227229, 04551-227230

College Name : Saranathan College of Engineering
University : Anna University Chennai
State : Tamil Nadu
City : Trichy
Contact number: 0431-2473682,2473284, 2473686

College Name : Sethu Institute of Technology
University : Anna University Tirunelveli
State :Tamil Nadu
City : Madurai
Contact number: 04566-255004, 04566 - 308001 , 04566-329971

College Name : Sri Sairam Engineering College
University : Anna University Chennai
State :Tamil Nadu
City : Chennai
Contact number:044-22380031, 044- 2251 2220 / 2251 2221 / 2251 2222 / 2223

College Name : Sri Sairam Institute of Technology
University : Anna University Chennai
State :Tamil Nadu
City : Chennai
Contact number:+91 44 2251 2111, +91 44 2251 2333

College Name : St. Joseph's College of Engineering
University : Anna University Chennai
State :Tamil Nadu
City : Chennai
Contact number: 044 - 2450 0782, 2450 0765, 044-2450 0792, 044-24501060

College Name : St. Joseph's College of Engineering & Technology
University : Anna University Chennai
State :Tamil Nadu
City : Thanjavur
Contact number:04362 282465

College Name : Thangavelu Group of Colleges
University : Anna University Chennai
State :Tamil Nadu
City : Chennai
Contact number:044 - 2450 1408, 2450 1409

College Name : Vivekanandha College of Engineering For Women
University : Anna University Coimbatore
State :Tamil Nadu
City : Tiruchengode
Contact number: +91-4288-234561, +91-4288-234562

This post will be regularly updated, so please stay tuned.

Friday, May 27, 2011

Cascade Control System

It there is more than one control systems are added together in a process the control system is called cascade control system.

Block diagram of cascade control system


The inherent interaction that occurs between two control systems in many applications is used in one control loop determined by measurement of a different variable for which interaction exists.


block diagram of cascade control system



Two measurements are taken from the system. Each is used in its own control loop. Set point of inner loop is decided by controller output of outer loop. Cascade control provides better control of the outer loop variable than is accomplished through a single variable system.

cascade control system process
Example of Cascade control system

The temperature controller generates the correction signal based on the actual temperature. This correction signal is used as the set point input to a flow controller. The flow controller signal positions the control valve, which regulates the flow of hot liquid from the vessel.

example of cascade control system
If temperature of heating tank fluid rises above the set point the temperature controller generates pneumatic signal which acts as the set point to the flow controller. Flow controller closes the control valve that decreases the flow of heating fluid so as to get the desired heating effect. Similarly the heating fluid temperature falls below the desired heating effect.

Advantages of cascade control system


The flow controller is much faster than the temperature controller due to much shorter dead time in the secondary loop than in the original single loop system.

The temperature controller with an integral mode remains in the design to ensure zero for all disturbance source.

Friday, May 13, 2011

List of Instrumentation and Control Engineering Companies in India

I have prepared a list of instrumentation and control engineering based companies in India, which you should must know.


National Instruments:

National Instruments transforms the way engineers and scientists around the world design, prototype, and deploy systems for test, control, and embedded design applications. Using NI open graphical programming software and modular hardware, customers at more than 30,000 companies annually simplify development, increase productivity, and dramatically reduce time to market. From testing next-generation gaming systems to creating breakthrough medical devices, NI customers continuously develop innovative technologies that impact millions of people.

If you are interested in this company you may send a mail to ni.india.resumes@ni.com.

ABB:

ABB is a global leader in power and automation technologies that enable utility and industry customers to improve their performance while lowering environmental impact.

Go to the Careers Section to Search Jobs

Larsen & Tourbo:

Larsen & Toubro Limited (L&T) is India's largest engineering and construction conglomerate with additional interests in electricals, electronics and IT. A strong customer-focus approach and constant quest for top-class quality have enabled L&T to attain and sustain leadership over 6 decades.

Website :  http://www.larsentoubro.com/
Instrumentation and control Jobs in Larsen & Tourbo here 

Robert Bosch

Robert Bosch is leading manufacture of automobile Instruments. Robert Bosch and Mico are jointly working in India.

Site Url :www.boschindia.com

Invensys

Designer and supplier of digital signal processing solutions and semiconductor products. Includes corporate and investor data, products, and employment.

website : www.invensys.com

GE

From jet engines to power generation, financial services to plastics, and medical imaging to news and information, GE people worldwide are dedicated to turning imaginative ideas into leading products and services that help solve some of the world's toughest problems.

website : www.ge.com

Suzlon

Suzlon Energy is Asia's strongest growing fully integrated wind power company and ranks amongst the top ten in the world. Suzlon integrates consultancy, design, manufacturing, operation and maintenance services to provide customers with total wind power solutions.

website : www.suzlon.com

Apna Technologies

ApnaTech is on the constant lookout for Intrepreneurs who are Excited about Personally Building a GREAT Organization and who can think miles ahead while focused on EXECUTING what they are doing right now with concrete understanding of the basics and passionate in Core Engineering.

Website : http://www.apnatech.com/careers
Drop in your resume to careers@apnatech.com

Whirlybird


Whirlybird Electronics was founded to establish a benchmark in the field of unmanned aerial vehicles (UAV) and unmanned ground vehicles (UGV). Our primary domain is Avionics with indigenous development of Inertial Navigation Systems (INS).

Website : http://www.whirlybird.in/index.html

Please checkout the list of various opening below & to apply, mail your resumes to: careers@whirlybird.in

ESSAR

Committed to innovative growth, Essar Group speaks the new language of success. The Group is judiciously invested in the commodity, annuity and services businesses

Website : http://www.essar.com/

be a part of the Essar family? careers@essar.com

Monday, April 11, 2011

Cathode Ray Tube - Electron Gun

This post is the continuation of the previous post on cathode ray tube.

The electron gun section of the cathode ray tube provides a sharply focused electron beam directed towards the fluorescent-coated screen. This section starts from thermally heated cathode, emitting the electrons. The control grid is given negative potential with respect to cathode. This grid controls the number of electrons in the beam, going to the screen.

The momentum of the electrons (their number * their speed) determines the intensity, or brightness, of the light emitted from the fluorescent screen due to the electron bombardment. The light emitted is usually of the green color. Because the electrons are negatively charged, a repulsive force is created by applying a negative voltage to the control grid (in CRT, voltages applied to various grids are stated with respect to cathode, which is taken as common point). This negative control voltage can be made variable.
electron gun inside crt

Note: a more negative voltage results in less number of electrons in the beam and hence decreased brightness of the beam spot.

Since the electron beam consists of many electrons, beam tends to diverge. This is because the similar (negative) charges on the electron repel each other. To compensate for such repulsion forces, an adjustable electrostatic field is created between two cylindrical anodes called the focusing anodes.

Note: the variable positive voltage on the second anode is used to adjust the focus or sharpness of the bright beam spot.

The high positive potential is also given to the preaccelerating anodes and accelerating anodes, which results into the required acceleration of the electrons.

Both focusing and accelerating anodes are cylindrical in shape having small openings located in the center of each electrode, co-axial with the tube axis. The preaccelerating and accelerating anodes are connected to a common positive high voltage which varies between 2 kV to 10 kV. The focusing anode is connected to a lower positive voltage of about 400V to 500V.

In the next post I will explain about the deflection system of cathode ray tube.

Saturday, April 9, 2011

Cathode Ray Tube (CRT)

The cathode ray Tube (CRT) is the heart of the C.R.O. the CRT generates the electron beam, accelerates the beam, deflects the beam and also has a screen where beam becomes visible as a spot. The main parts of the CRT are:

  1. Electron Gun
  2. Deflection system
  3. Fluorescent screen
  4. Glass tube or envelope
  5. Base

A schematic diagram of CRT, showing its structure and main components is shown in the figure below.

cathode ray tube


Since I want to explain each and every parts of the CRT in detail, I will spilt this topic into 3 parts.

Friday, April 8, 2011

What is Cathode Ray oscilloscope?

In studying the various electronic, electrical networks and systems, signals which are functions of time, are often encountered. Such signals may be periodic or non-periodic in nature. The device which allows, the amplitude of such signals, to be displayed primarily as a function of time is called cathode ray oscilloscope, commonly known as CRO. The C.R.O gives the Visual representation of the time varying signals. The oscilloscope has become an universal instrument and is probably most versatile tool for the development of electronic circuits and systems. It is an integral part of electronic laboratories.



The oscilloscope is, in fact, a voltmeter. Yes, you read it right. It is in fact, a voltmeter. Instead of the mechanical deflection of a metallic pointer as used in the normal voltmeters, the oscilloscope uses the movement of a visible spot. The movement of such spot on the screen is proportional to the varying magnitude of the signal, which is under measurement.

The electron beam can be deflected in two directions: the horizontal or x-direction and the vertical or y-direction. Thus an electron beam producing a spot can be used to produce two dimensional displays. Thus C.R.O can be regarded as a fast x-y plotter. The x-axis and y-axis can be used study the variation of one voltage as a function of another. Typically the x-axis of the oscilloscope represents the time while the y-axis represents variation of the input voltage signal. Thus if the input voltage signal applied to the y-axis of C.R.O is sinusoidally varying and if x-axis represents the time axis, then the spot moves sinusoidally, and the familiar sinusoidal waveform can be seen on the screen of the oscilloscope. The oscilloscope is so fast device that it can display the periodic signals whose time period is as small as microseconds and even nanoseconds. The C.R.O basically operates on voltages, but it is possible to convert current, pressure, strain, acceleration and other physical quantities into the voltage using transducers and obtain their visual representations on the C.R.O.

Thursday, March 24, 2011

Temperature compensation and Error in PMMC:

The basic pmmc instrument is sensitive to the temperature. The magnetic field strength and spring tension decrease with increase in temperature. The coil resistance increases with increase in the temperature. Thus pointer reads low for a given current. The meter tends to read low by approximately 0.2% per Celsius rise in the temperature. Hence the temperature compensation is provided by appropriate use of series and shunt resistance of copper and manganin.

Temperature compensation


The simple temperature compensation circuit for PMMC uses a resistance in series with a movable coil, as shown in the figure. The resistor is called swamping resistor. It is made up of manganin having practically zero temperature coefficients, combined with copper in the ratio of 20/1 or 30/1.
temperature compensation for pmmc

The resultant resistance of the coil and the swamping resistor increases slightly as temperature increases, just enough to compensate the change in springs and magnet due to temperature. Thus the effect of temperature is compensated.

More complicated but complete cancellation of temperature effects can be obtained by using the swamping resistors in series and parallel combination as shown in figure.

advanced temperature compensation for pmmc


In this circuit, by correct proportioning of copper and manganin parts, complete cancellation of the temperature effects can be achieved.

Errors in PMMC Instrument


The basic sources of error in PMMC instruments are friction, temperature and aging of various parts. To reduce the frictional errors ratio of torque to weight is made very high.

The most serious errors are produced by the heat generated or by changes in the temperature. This changes the resistance of the working coil, causing large errors. In case of voltmeters, a large series resistance of very low temperature coefficient is used. This reduces the temperature errors.

The aging of permanent magnet and control springs also cause errors. Opposite errors in PMMC is caused by weakening of magnet and spring cause. The weakening of magnet causes less deflection while weakening of control springs cause large deflection, for a particular value of current. The proper use of material and pre-ageing during manufacturing can reduce the errors due to weakening of control springs.

Wednesday, March 23, 2011

Permanent magnet moving coil instruments (PMMC)


The permanent magnet moving coil instruments are most accurate type for direct current measurements. The action of these instruments is based on the motoring principle. When a current carrying coil is placed in the magnetic field produced by permanent magnet, the coil experiences a force and moves. As the coil is moving and the magnet is permanent, the instrument is called permanent magnet moving coil instrument. This basic principle is called D’Arsonval principle. The amount of force experienced by the coil is proportional to the current passing through the coil.

The PMMC instrument is shown in the below images.

permanent magnet moving coil


The moving coil is either rectangular or circular in shape. It has number of turns of fine wire. The coil is suspended so that it is free to turn about its vertical axis. The coil is placed in uniform, horizontal and radial magnetic field of a permanent magnet in the shape of a horse-shoe. The iron core is spherical if coil is circular and is cylindrical if the coil is rectangular. Due to iron core, the deflecting torque increase, increasing the sensitivity of the instrument.

The controlling torque is provided by two phosphor bronze hair springs.

The damping torque is provided by eddy current damping. It is obtained by movement of aluminum former, moving in the magnetic field of the permanent magnet.

The pointer is carried by the spindle and it moves over a graduated scale. The pointer has light weight so that it deflects rapidly. The mirror is placed below the pointer to get the accurate reading by removing the parallax. The weight of the instrument is normally counter balanced by the weights situated diametrically opposite and rapidly connected to it. The scale markings of the basic d.c PMMC instruments are usually linearly spaced as the deflecting torque and hence the pointer deflections are directly proportional to the current passing through the coil.

The top view of PMMC instrument is shown in the below image.
pmmc top view

Advantages of PMMC


The various advantages of PMMC instruments are,

It has uniform scale.
With a powerful magnet, its torque to weight ratio is very high. So operating current of PMMC is small.
The sensitivity is high.
The eddy currents induced in the metallic former over which coil is wound, provide effective damping.
It consumes low power, of the order of 25 W to 200 mW.
It has high accuracy.
Instrument is free from hysteresis error.
Extension of instrument range is possible.
Not affected by external magnetic fields called stray magnetic fields.

Disadvantages of PMMC


The various disadvantages of PMMC instruments are ,

PMMC is Suitable for direct current measurement only.
Ageing of permanent magnet and the control springs introduces the errors.
The cost is high due to delicate construction and accurate machining.
The friction is due to jewel-pivot suspension.

Tuesday, November 23, 2010

Installation of Strain Gauge Video Post

Hello Reader time for real watch about strain gauge and how to install them, this video is Presented by a YouTube user Binsfledengineering


Post you comments below.


Sunday, May 30, 2010

Data acquisition system

Data acquisition systems are used for large number of applications in industrial and scientific areas like aerospace and telemetry industries. Data acquisition system rapidly collects bulky of data, processing it and stores or displays the desired result.

Data acquisition system

The generalized block diagram of data acquisition system is shown in figure. It consists of sensors with signal conditioning, multiplexing, data conversion stage and display system.

Transducer converts physical parameters such as temperature, pressure, acceleration, weight, displacement, etc,. Into electrical quantities like voltage, resistance or frequency, which is an acceptable by the acquisition system. Signal conditioner modifies or amplifies transducer output signal. It includes circuits for providing excitation power to the transducer.

Multiplexer accepts multiple analog inputs and sequentially connects them to any one of the measuring instruments. ADC (analog to digital converter) converts the analog voltage to its equivalent digital form. Either ADC output is fed to any of the measuring devices or it may feed to digital computer for data reduction and further processing.

Tuesday, May 18, 2010

Moving coil galvanometer:

                   The principle of moving coil galvanometer is that when a conductor carrying current is placed in a magnetic field, it experience a force. The construction of a moving coil galvanometer is as shown in the figure. A rectangular coil is suspended in between the poles of a powerful magnet by means a phosphor bronze wire. The magnet is bored out cylindrically so that the field is radial. A soft iron core is placed inside the coil to induce large number of magnetic lines. A mirror M is fixed on the phosphor bronze wire. A spring is fixed at the bottom of the coil.


                     Let B be the strength of the magnetic field, n be the number of turns in the coil, A be the area of the coil and I be the current flowing through the coil.

            The deflecting couple produced in the coil
                            = BIAn.

        Due to this deflecting couple, the coil rotates and this couple is opposed by the torsional couple produced in the phosphor bronze wire.

                             The restoring couple produced in the coil
                                         =Cθ

                Where, C is couple per unit twist of the wire and θ is the angle of twist which can be measured by means of a lamp and scale arrangement.

  At equilibrium,

                             BIAn = Cθ

                             i.e., I = (C/BAn) * θ

            since, C,B,A and n are constants, the defelction in the coil is directional in the coil is directly proportional to the current through the coil.

Saturday, May 15, 2010

Error Analysis

                Measurement is a process of comparing an unknown quantity with a standard quantity . No measurement can be made with perfect accuracy which results in the occurance of the errors.

There are two types of error,
  • Absolute error
  • Percentage error

Absolute error:

           Absolute error may be defined as the difference between the variable and measured value of the variable it can be expressed as e=yn-xn

Where, e = absolute error
Yn= expected value
Xn = measured value

Percentage error:

Percentage error = absolute error*100/expected error

Where, A = yn-xn*100/yn

Thursday, May 13, 2010

What are Transducers ?

        Transducers play an important role in the field of instrumentation and control engineering. Any energy in a process should be converted from one form into another form to make the communication from one rectification sector to another.

            Transducer is a device which converts one form of energy into another form i.e,. the given non-electrical energy is converted into an electrical energy.

Types of transducers:

There are two types of transducers, they are:

  • Active transducers
  • Passive transducers
Active transducers:
Active transducer is a device which converts the given non-electrical energy into electrical energy by itself. Thermocouple, Photovoltaic cell and more are the best examples of the transducers


Passive transducers:
Passive transducer is a device which converts the given non-electrical energy into electrical energy by external force. Resistance strain gauge, Differential Transformer are the examples for the Passive transducers.

Tuesday, May 11, 2010

Linear Variable Displacement Transducer (LVDT):


Update:Linear Variable Displacement Transducer (LVDT):

A very basic transducer which is always useful in the field of instrumentation, I have studied about this in my college days. Now let me explain about the LVDT with its Principle of Operation and I will explain how it is constructed for its well known operation and you can understand the working of LVDT.


Principle of LVDT:

LVDT works under the principle of mutual induction, and the displacement which is a non-electrical energy is converted into an electrical energy. And the way how the energy is getting converted is described in working of LVDT in a detailed manner.


Construction of LVDT:

LVDT consists of a cylindrical former where it is surrounded by one primary winding in the centre of the former and the two secondary windings at the sides. The number of turns in both the secondary windings are equal, but they are opposite to each other, i.e., if the left secondary windings is in the clockwise direction, the right secondary windings will be in the anti-clockwise direction, hence the net output voltages will be the difference in voltages between the two secondary coil. The two secondary coil is represented as S1 and S2. Esteem iron core is placed in the centre of the cylindrical former which can move in to and fro motion as shown in the figure. The AC excitation voltage is 5 to 12V and the operating frequency is given by 50 to 400 HZ.



Working of LVDT:

Let's study the working of LVDT by splitting the cases into 3 based on the iron core position inside the insulated former.


Case 1:


On applying an external force which is the displacement, if the core reminds in the null position itself without providing any movement then the voltage induced in both the secondary windings are equal which results in net output is equal to zero


i.e., Esec1-Esec2=0


Case 2:

When an external force is appilied and if the steel iron core tends to move in the left hand side direction then the emf voltage induced in the secondary coil is greater when compared to the emf induced in the secondary coil 2. Therefore the net output will be Esec1-Esec2



Case 3:

When an external force is applied and if the steel iron core moves in the right hand side direction then the emf induced in the secondary coil 2 is greater when compared to the emf voltage induced in the secondary coil 1. therefore the net output voltage will be Esec2-Esec1


Advantages of LVDT:


* Infinite resolution is present in LVDT
* High output
* LVDT gives High sensitivity
* Very good linearity
* Ruggedness
* LVDT Provides Less friction
* Low hysteresis
* LVDT gives Low power consumption.


Disadvantages of LVDT:

* Very high displacement is required for generating high voltages.
* Shielding is required since it is sensitive to magnetic field.
* The performance of the transducer gets affected by vibrations
* Its is greatly affected by temperature changes.

Applications of LVDT:

LVDT is used to measure displacement ranging from fraction millimeter to centimeter.

Acting as a secondary transducer, LVDT can be used as a device to measure force, weight and pressure, etc..